Skip to main content

Tebbetts-style breast retractor 80mm long x 16mm wide blade serrated end with fiberoptics and suction

  • Tebbetts-style design supports controlled tissue retraction in general and plastic surgery.
  • The 80mm length provides practical reach for breast retraction procedures.
  • A 16mm-wide blade helps maintain focused access within the operative field.
  • Serrated blade end supports secure engagement during tissue retraction.
  • Integrated fiberoptics help illuminate the retraction area during procedures.
  • Suction capability supports fluid management during breast retraction procedures.

العلامة التجارية: surgivalley

Volume Price Breaks (RTS) Factory Direct
1 - 9 pcs
$46.52
Sample Order
10 - 49 pcs
$39.54
-15%
50 - 99 pcs
$34.89
-25%
100+ pcs
$30.24
-35%
Estimated Order Total: $46.52 ($46.52/pc)
Direct Sialkot Surgical Forge & Clinical Manufacturing Assurance
CE MDR & FDA Registered EMDN: L03140199 GMDN: 45918
Direct Sialkot Surgical Forge 35–45% procurement savings vs EU/US middlemen
AISI 420 / 440A German Stainless DIN 1.4021 metallurgy, 48–54 HRC, ASTM A967
134°C Autoclave Reusable Steam sterilizable with DIN silicone cassette durability
Low MOQ Hospital & Clinic Sets Custom procedure packs with laser UDI batch traceability
<24h Clinical Spec Review In-house precision tip geometry & sample benchmarking
الكمية
View Quote (0)
(متوفر)
Added to quote! View Quote Cart
OEM & International Cross-Reference Equivalents
UNIVERSAL NOMENCLATURE EU MDR 2017/745 & US FDA GUDID Classification
EMDN (EUDAMED): L03140199
SPREADERS AND RETRACTORS FOR GENERAL SURGERY, REUSABLE - OTHER
REUSABLE SURGICAL INSTRUMENTS > GENERAL SURGERY INSTRUMENTS, REUSABLE > GENERAL SURGERY SPREADERS AND SPATULAS, REUSABLE > GENERAL SURGERY SPREADERS AND RETRACTORS, REUSABLE > SPREADERS AND RETRACTORS FOR GENERAL SURGERY, REUSABLE - OTHER
GMDN Code: 45918
Hand-held surgical retractor, reusable
Manufacturer / Benchmark Catalog Number (REF) Specification Match
Medline PF18472 Exact Pattern Match

Notice of Nominative Fair Use: All manufacturer names, trademarks, symbols, and catalog part numbers are referenced solely for comparative identification, cross-reference, and equipment compatibility guidance. SurgiValley is an independent surgical manufacturer and is not affiliated with, sponsored by, or endorsed by any of the respective trademark owners.

رمز المنتج: 005212682

EMDN (EUDAMED): L03140199 (SPREADERS AND RETRACTORS FOR GENERAL SURGERY, REUSABLE - OTHER)

GMDN Code: 45918 (Hand-held surgical retractor, reusable)

الفئات: جراحة تجميلية, مجموعات الأدوات الجراحية, مجموعات جراحة التجميل, المباعدات, مبعدات

Controlled Access and Clear Visualization for Breast Retraction

The Tebbetts-style breast retractor is a surgical retractor designed to hold tissue aside and support access during procedures requiring focused exposure. Its 80mm length and 16mm-wide blade provide a defined working profile for positioning within the operative field, while the serrated end is intended to support secure tissue engagement. Integrated fiberoptics and suction bring illumination and fluid-management functions together at the instrument, helping streamline handling where visibility and access are important. Suitable for general surgery and plastic surgery applications, this configuration supports practical retraction tasks without requiring separate illumination or suction instruments at the point of use.

Use Cases

  • Support breast retraction during general surgery procedures requiring controlled tissue displacement and operative access.
  • Assist with tissue positioning and exposure in plastic surgery workflows involving breast-focused operative fields.
  • Use the serrated blade end when a more secure engagement point is needed during retraction.
  • Employ the integrated fiberoptics to provide localized illumination at the retractor during access and visualization tasks.
  • Use the integrated suction function where fluid removal is part of the retraction workflow.

Care & Reprocessing

  • Clean and reprocess the retractor according to facility protocols and the applicable instructions for use.
  • Inspect the serrated blade end before and after use for visible damage, deformation, or retained debris.
  • Handle the fiberoptic and suction components carefully during cleaning, transport, and setup to help prevent damage.
  • Store the retractor in a manner that protects the blade, fiberoptic components, and suction features from impact or distortion.

Specifications

Overall Length8 cm
Length (cm)8 cm
Coating/MaterialAISI 420 German Stainless Steel
Tip TypeSerrated Jaws

General use; follow facility protocols.

Technical Specifications

Width16mm

Width 16mm
Overall Length 8 cm
Length (cm) 8 cm
Jaw Pattern Serrated
Coating/Material AISI 420 German Stainless Steel
Tip Type Serrated Jaws
No product reviews yet
Write Your Review
Please login to write a review!

Be the first to review this product

Share relevant product experience to help other buyers make an informed decision.

Help other buyers understand the product