Skip to main content

Mini Thoracotomy Retractor with 3 Blades for Cardiovascular and General Surgery Procedures

  • Designed for mini thoracotomy access during cardiovascular and general surgery procedures.
  • Three blades support controlled tissue retraction while maintaining a focused operative field.
  • Mini construction helps support access where compact retraction is needed.
  • Provides practical exposure support across cardiovascular and general surgical workflows.
  • Retractor configuration helps organize tissue positioning during focused procedures.
  • Supports practical visualization when controlled thoracic exposure is required.

Brand: surgivalley

Volume Price Breaks (RTS) Factory Direct
1 - 9 pcs
$40.53
Sample Order
10 - 49 pcs
$34.45
-15%
50 - 99 pcs
$30.40
-25%
100+ pcs
$26.34
-35%
Estimated Order Total: $40.53 ($40.53/pc)
Direct Sialkot Surgical Forge & Clinical Manufacturing Assurance
CE MDR & FDA Registered EMDN: L03140199 GMDN: 45918
Direct Sialkot Surgical Forge 35–45% procurement savings vs EU/US middlemen
AISI 420 / 440A German Stainless DIN 1.4021 metallurgy, 48–54 HRC, ASTM A967
134°C Autoclave Reusable Steam sterilizable with DIN silicone cassette durability
Low MOQ Hospital & Clinic Sets Custom procedure packs with laser UDI batch traceability
<24h Clinical Spec Review In-house precision tip geometry & sample benchmarking
Menge
View Quote (0)
(250 Produkte verfügbar)
Added to quote! View Quote Cart
OEM & International Cross-Reference Equivalents
UNIVERSAL NOMENCLATURE EU MDR 2017/745 & US FDA GUDID Classification
EMDN (EUDAMED): L03140199
SPREADERS AND RETRACTORS FOR GENERAL SURGERY, REUSABLE - OTHER
REUSABLE SURGICAL INSTRUMENTS > GENERAL SURGERY INSTRUMENTS, REUSABLE > GENERAL SURGERY SPREADERS AND SPATULAS, REUSABLE > GENERAL SURGERY SPREADERS AND RETRACTORS, REUSABLE > SPREADERS AND RETRACTORS FOR GENERAL SURGERY, REUSABLE - OTHER
GMDN Code: 45918
Hand-held surgical retractor, reusable
Manufacturer / Benchmark Catalog Number (REF) Specification Match
Aesculap BT466R Exact Pattern Match
Buxton Biomedical 24-6302 Exact Pattern Match
Medline PF181258 Exact Pattern Match
RZ-Medizintechnik 225-400-102 Exact Pattern Match
Teleflex 841030 Exact Pattern Match

Notice of Nominative Fair Use: All manufacturer names, trademarks, symbols, and catalog part numbers are referenced solely for comparative identification, cross-reference, and equipment compatibility guidance. SurgiValley is an independent surgical manufacturer and is not affiliated with, sponsored by, or endorsed by any of the respective trademark owners.

SKU: 005210728

EMDN (EUDAMED): L03140199 (SPREADERS AND RETRACTORS FOR GENERAL SURGERY, REUSABLE - OTHER)

GMDN Code: 45918 (Hand-held surgical retractor, reusable)

Kategorien: Wundhaken, Retraktoren | Rippenspreizer

Tags: thoracotomy

Compact Three-Blade Retraction for Thoracotomy Access

The Mini Thoracotomy Retractor with 3 Blades is a surgical retractor intended to support tissue retraction and maintain working access during thoracotomy-related procedures. Its compact format and three-blade configuration provide a practical approach for organizing the operative field where controlled exposure is required. The instrument is suited to both cardiovascular and general surgery workflows, allowing teams to incorporate one retraction solution across approved applications. By supporting access and visualization during hands-on surgical tasks, it can contribute to a more orderly instrument setup while helping clinicians manage the operative field according to facility technique and procedure requirements.

Use Cases

  • Support tissue retraction during cardiovascular surgery procedures involving thoracotomy access.
  • Assist with operative-field exposure during general surgery procedures where thoracotomy retraction is required.
  • Use the three-blade configuration to help maintain access while the surgical team performs task-focused work within the thoracic operative field.
  • Integrate into cardiovascular and general surgery instrument setups where a compact thoracotomy retractor is appropriate.

Care & Reprocessing

  • Clean and reprocess the retractor according to facility protocols and the applicable instructions for use.
  • Inspect the blades and retractor structure before and after use for visible soil, damage, deformation, or impaired function.
  • Handle the three-blade assembly carefully during cleaning, transport, and setup to avoid unnecessary impact or distortion.
  • Store the instrument in a clean, protected location that helps prevent damage and contamination.

Specifications

Specifications

Coating/MaterialAISI 420 German Stainless Steel

General use; follow facility protocols.

Technical Specifications

Coating/MaterialAISI 420 German Stainless Steel
MaterialAISI 420 Martensitic Stainless Steel

Coating/Material AISI 420 German Stainless Steel
Material AISI 420 Martensitic Stainless Steel
Tip Type Standard
No product reviews yet
Write Your Review
Please login to write a review!

Be the first to review this product

Share relevant product experience to help other buyers make an informed decision.

Help other buyers understand the product